“3084 Speed Level™ Sigma Lift” Service and Parts Manual
November 2009
Page 4a-14
T
R O U B L E S H O O T I N G
- 3 0 8 4 R T
M O D E L S
- - E Z - C
A L
A
D J U S T M E N T
5F
OUTRIGGERS
Called
“Outriggers”
on
the EZ-Cal,
these
personalities
effect
Auto-level
function
5F-1
Outriggers
2
Not Used
5F-2
Extend
50%
O/R speed before all legs down
5F-3
Level
35%
O/R speed after all legs touch down
5F-4
Retract
55%
Maximum speed potential
5F-5
Debounce
0.35
Compensates for switch bounce
5F-6
Initial
0.5
Not Used
5F-7
Tilt filter
6
Compensates for tilt sensor free movement
5F-8
X Tilt target
0.2 deg
Target level stops movement
5F-9
Y Tilt target
0.2 deg
Target level stops movement
5F-10
Tilt Slack
0.3 deg
Additional compensation
5F-11
Outrigger Test
Yes/No
Not Used
5G
GROUND MODE
Lower Control
Operations
5G-1
UP
53%
Maximum speed potential
5G-2
DOWN
0%
Gravity down
5G-3
OUT
0%
Power deck operation (not used)
5G-4
IN
0%
Power deck operation (not used)
5G-5
ACCEL
1.0 sec
Ramp-up time to maximum
5G-6
DECEL
1.0 sec
Ramp-down drive output
5H
TILT
5H-1
X Trip
2.0 degrees
Angle tilt sensor signals Out Of Level
5H-2
Y Trip
2.0 degrees
Angle tilt sensor signals Out Of Level
5H-3
Delay Trip
2.0 sec
Time delay between Tip and Signal
5H-4
Delay Clear
0.5 sec
Time delay between Tip and Signal OFF
TILT 2
5H-4
Tilt 2
—
Sub category, press ENTER to access
Sub Menu
5H-5A
At Height
101%
Point where lesser tilt angle used
5H-5B
X Trip 2
1.5 sec
Not Used
5H-5C
Y Trip 2
1.5 sec
Not Used
5I
OVERLOAD
ANSI:
values = 0
CE:
values apply
5I-1
Trip @
ANSI:
0% ||
CE:
110%
% of weight over maximum to trigger overload
5I-2
Lamp @
ANSI:
0% ||
CE:
0%
% of weight over maximum to trigger lamp
5I-3
Alarm @
ANSI:
0% ||
CE:
0%
% of weight over maximum to trigger alarm
5I-4
@ Height
ANSI:
0% ||
CE:
8%
% of elevation load sense starts monitoring weight
5I-5
Safe Down
ANSI:
0% ||
CE:
12%
% of elevation lift-down still operates in overload
5I-6
Delay Trip
1.5 sec
Delay before overload trip
5I-7
Delay Clear
1.5 sec
Delay before overload clear
OVERLOAD 2
5I-8
Overload # 2
—
Sub category, press ENTER to access
Sub Menu
5I-8a
@ Height
0%
% of height for secondary overload valve
5I-8b
Scale
100%
% of reduced overload valve
5J
ALARMS
5J-1
Drive: Yes/No
No
1
= FWD
2
= REV
3
= Both
4
= All Motion
5J-2
Lift
2 = Down
1
= UP
2
= DOWN
3
= Both
4
= All Motion
5J-3
Tilt
1 = When Elevated
1
= When Elevated
2
= Always
5K
HEIGHTS
5K-1
Elevation
15%
Point at which machine enters elevated mode
5K-2
Maximum Drive
101%
Maximum drivable height
5K-3
Maximum Lift
ANSI:
101% ||
CE:
98%
Maximum elevated height potential
5K-4
Armguard
101%
Stops descent for 5 sec
5K-5
Overload
ANSI:
0% ||
CE:
8%
% of elevation load sense starts monitoring weight
5K-6
Safe Down
ANSI:
0% ||
CE:
12%
% of elevation lift-down still operates in overload
5K-7
Overload # 2
0%
Not Used
5K-8
Tilt # 2
ANSI:
0% ||
CE:
0%
Reduced degree of tilt at % elevation
Table 4a-1: EZ-Cal Adjustment Table
OPERATION
ID
PERSONALITY
FACTORY SETTING
EXPLAINATION
Содержание Speed Level 2684 ES
Страница 52: ...3084 Speed Level Sigma Lift Service and Parts Manual October 2009 Page 1 32 GENERATOR OPTION 3084RT NOTES...
Страница 104: ...3084 Speed Level Sigma Lift Service and Parts Manual November 2009 Page 3 20 ENGINE MAINTENANCE NOTES...
Страница 142: ...3084 Speed Level Sigma Lift Service and Parts Manual November 2009 Page 4a 38 TROUBLESHOOTING 3084RT MODELS NOTES...