“3084 Speed Level™ Sigma Lift” Service and Parts Manual
November 2009
Page 4a-15
T
R O U B L E S H O O T I N G
- 3 0 8 4 R T
M O D E L S
- - E Z - C
A L
A
D J U S T M E N T
E Z - C
A L
S
E T U P
Refer to "Using the EZ-cal Scan Tool" on page 4a-7
Table 4a-2: EZ-Cal Setup Table
OPERATION
ID
PERSONALITY
FACTORY SETTING
EXPLAINATION
6A
CHANGE
DEFAULTS
6A-1
Customer
5: XX84RT
Identifies Base Model
Must be set when GP400 is Replaced
6A-2
Model
5 = ANSI
6 = CE
Select from these choices only
6D
TILT SETUPS
6B-1
Calibrate Level?
Y = ENTER N = ESC
Follow instructions in
Section 2 - Level Sensor Calibration
WARNING! Refer to Tilt Sensor Calibration instructions before attempting calibration
6B-2
Tilt Shutdown
0 = Never
Function shutdown tilted when platform stowed
6B-3
Elevated Shutdown
1 = Lift & Drive
Function shutdown tilted when platform elevated
6B-4
Axle Tilt
3.0 deg
Maximum deflection of axle before elevated drive
interlock
6C
HEIGHT SETUP
(CE OPTION ONLY)
6C-1
Elevation @
13%
6C-2
Calibrate Height
Start Calibration
See Section 2 for calibration of Height Sensor
6C-3
Minimum Lift
1.0 sec
Calibration setting - do not change
6C-4
Samples
0.10 sec
Calibration setting - do not change
6C-5
Tilt Correction
Disabled
Calibration setting - do not change
6C-6
Slow Down
10%
Calibration setting - do not change
6D
LOAD SETUPS
(CE OPTION ONLY)
6D-1
Calibrate Load
Start Calibration
See Section 2 for calibration of
CE Overload System
6D-2
Faulty Load
100%
Calibration setting - do not change
6D-3
Dynamic Scale
95%
Calibration setting - do not change
6D-4
Delay Up
0.0 sec
Not Used
6D-5
Delay Down
0.0 sec
Not Used
6E
INTERLOCKS
6E-1
Trigger Only
10.0 sec
Enable bar held without operation before interlock
6E-2
Trigger Wait
0.0 sec
Delay after enable bar pulled before function
enabled
6E-3
Function hold
0.2 sec
Function enabled after operator release
Delays
6E-4
Delays
—
Sub category, press ENTER to access
Sub Menu
6E-4a
Throttle Delay
0.0 sec
Delay before throttle enabled
6E-4b
Start Delay
10.0 sec
Interlocks start to protect start system from
overheat
Содержание Speed Level 2684 ES
Страница 52: ...3084 Speed Level Sigma Lift Service and Parts Manual October 2009 Page 1 32 GENERATOR OPTION 3084RT NOTES...
Страница 104: ...3084 Speed Level Sigma Lift Service and Parts Manual November 2009 Page 3 20 ENGINE MAINTENANCE NOTES...
Страница 142: ...3084 Speed Level Sigma Lift Service and Parts Manual November 2009 Page 4a 38 TROUBLESHOOTING 3084RT MODELS NOTES...