“3084 Speed Level™ Sigma Lift” Service and Parts Manual
November 2009
Page 4b-26
T
R O U B L E S H O O T I N G
- 3 0 8 4 E S
M O D E L
- - E
Z
- C
A L
R
E T R I E V E
M
O D E
A
N D
H
E L P
M
E S S A G E S
P 6 0 0 T E M P E R AT U R E M
E S S A G E S
This section lists “temperature” HELP messages – problems have been detected which
are likely due to excessive duty cycling or poor heatsinking:
FAULT: BAD INTERNAL TEMPERATURE SENSOR! ___________ Flash Code: 4/1
• The heatsink temperature is out of range; if the fault remains, the power controller may have
to be replaced.
FUNCTIONS LOCKED - TOO HOT! _________________________ Flash Code: 4/2
• The heatsink temperature exceeds 75ºc, preventing all functions except lowering. Check for
excessive motor current draw; check for good heatsinking to vehicle chassis.
S U P P LY M
E S S A G E S
The following are “supply” HELP messages – problems have been detected which are
likely due to supply issues:
FAULT: BAD INTERNAL 5V!_______________________________ Flash Code: 4/2
• The internal “5V slave” supply is out of range; if the fault remains, the controller may have to
be replaced.
FAULT: BAD INTERNAL SLAVE! ___________________________ Flash Code: 4/2
• The internal “slave” is not operating correctly; if the fault remains, the controller may have to
be replaced.
FAULT: BAD INTERNAL 12V!______________________________ Flash Code: 4/3
• The internal “12V” supply is out of range;
• 12V Supply is generated by the Motor control module and supplied to the GP400. Check for
wiring errors between the two modules. If the fault remains, the Motor Controller may have to
be replaced.
FAULT: BATTERY VOLTAGE TOO LOW! _____________________ Flash Code: 4/4
• The battery supply is too low – the batteries must be re-charged.
FAULT: BATTERY VOLTAGE TOO HIGH! ____________________ Flash Code: 4/4
• The battery supply is too high – check that the correct battery and charger are installed.
FAULT: BAD 5V SENSOR SUPPLY - CHECK P2-1 WIRING! _____ Flash Code: 4/5
• The “5V sensor” supply is out of range; this supply is available to power external 5V-powered
sensors – check that is has not been overloaded or short-circuited to other wiring (CE mod-