“3084 Speed Level™ Sigma Lift” Service and Parts Manual
November 2009
Page 4a-18
T
R O U B L E S H O O T I N G
- 3 0 8 4 R T
M O D E L S
- - E Z - C
A L
A
D J U S T M E N T
2F
OUTPUTS
2F-1
P4-1
Choke (gas engine) or pre-heat (diesel). ON= Choke or Pre-heat activated
2F-2
P4-2
Engine Start. ON= Starter activated
2F-3
P4-4
Throttle Solenoid. ON= Throttle solenoid pulled in
2F-4
P4-5
Fuel to fuel select switch. ON= fuel system activated
2F-5
P4-6
Fuel to fuel select switch. ON= fuel system activated
2F-6
P4-7
Alternator Excite. ON= power to activate alternator charge
2F-7
P4-8
Ignition. ON= power to ignition coil (gas) or fuel hold solenoid (diesel)
2F-8
P4-10
Rear Wheel Bi-pass Valves. ON= Valves powered, rear wheels in bi-pass
2F-9
P4-12
Proportional Valve. ON= Proportional valve activated for lift and drive operation
2F-10
P4-14
Down Valves. ON= Down valves activated for platform lower operation
2F-11
P5-1
Lift Valve. ON= Lift valve activated for platform Lift
2F-12
P5-2
Steer Right. ON= steer right valve activated
2F-13
P5-3
Steer Left. ON= steer left valve activated
2F-14
P5-4
Drive Forward. ON= drive forward valve activated
2F-15
P5-5
Drive Reversed. ON= drive reverse valve activated
2F-16
P5-6
Alarm. ON= alarm activated (default alarm in Down, may be selected for other
modes)
2F-17
P5-7
High Torque. ON= high torque valve activated (drive range toggle in down
position)
2F-18
P5-8
High Speed. ON= high speed valve activated (drive range toggle in up position)
2F-19
P5-9
Hour Meter. ON= Meter powered up
2F-20
P5-12
Power Supply to limit switch and TBM module - should be ON when system
powered
2F-21
P6-1
Rear Pitching Valve. ON= rear pitching valve activated for Platform Rear Leveling
2F-22
P6-2
Front Pitching Valve. ON= Front Pitching valve activated for Platform forward
Level
2F-23
P6-3
Outrigger – Not used
2F-24
P6-4
Left Rolling Valve. ON= Left valve activated for platform Level Left
2F-25
P6-11
Axle Lock Valves. ON= Axle valves powered, front axle will oscillate
2G
LOG
2G-1
Cal Date
Date of Load Sense calibration (CE option only)
2G-2
Software
MEC specific software version
2G-3
Powered
Accumulated time GP400 powered up (red LED on)
Table 4a-3: EZ-Cal Diagnostics Menu
SELECTION
ID
EZ-cal
READOUT
EXPLAINATION
Содержание Speed Level 2684 ES
Страница 52: ...3084 Speed Level Sigma Lift Service and Parts Manual October 2009 Page 1 32 GENERATOR OPTION 3084RT NOTES...
Страница 104: ...3084 Speed Level Sigma Lift Service and Parts Manual November 2009 Page 3 20 ENGINE MAINTENANCE NOTES...
Страница 142: ...3084 Speed Level Sigma Lift Service and Parts Manual November 2009 Page 4a 38 TROUBLESHOOTING 3084RT MODELS NOTES...