“3084 Speed Level™ Sigma Lift” Service and Parts Manual
November 2009
Page 2-4
E
L E C T R I C A L
S
Y S T E M
– G
E N E R A L
S
TART
D
ELAY
L
IGHT
- 3084RT
The START DELAY light is located on the Lower Control box (see Figure 2-4 on
Page 2-8).
The machine is equipped with a start system protective device, controlled by the
GP400. This protects the starter and related parts from damage caused by over-
cranking in hard starting situations.
• Maximum starter operation time is 10 seconds.
• If no start, the START DELAY light will illuminate and the starter will be disabled for 35 sec-
onds.
• When the START DELAY light goes OFF the starter will operate.
B
ATTERY
D
ISCONNECT
S
WITCH
Figure 2-3:
Master Disconnect Switch
All electrical power is routed through the Master
Disconnect switch located in the Control Module. The
switch can be locked in the OFF position with a padlock
to prevent unauthorized use.