T
R O U B L E S H O O T I N G
- 3 0 8 4 R T
M O D E L S
- - E
Z
- C
A L
R
E T R I E V E
M
O D E
A
N D
H
E L P
M
E S S A G E S
O T H E R M
E S S A G E S
The following are other HELP messages:
SOME BIG BAD PROBLEM! ______________________________ Flash Code: 9/9
• This message should not occur!
FACTORY OVERRIDE ___________________________ Flash Code: (fast flashing)
• When the controller is first shipped, prior to initial calibration, it is configured in a special “fac-
tory override” state. In this state, none of the normal shutdowns or interlocks will occur – the
vehicle can be freely lifted/lowered and driven irrespective of any calibration needs, vehicle tilt,
etc.
• As soon as an EZ-Cal is connected to the controller, the factory override state is ended.
• If calibration does not occur, then the factory override state will recur if the EZ-Cal is discon-
nected and power is switched off/on.
IMPORTANT: – Never use a vehicle in factory override; this state is ONLY intended
for use during manufacture! While factory override is active, the LED is rapidly
flashed on/off.