“3084 Speed Level™ Sigma Lift” Service and Parts Manual
November 2009
Page 2-22
G P 4 0 0 C
O N T R O L
M
O D U L E
S
E T U P
9. Press Enter.
• Display reads PLEASE LIFT.
10. Hold lower controls switch in the up position until machine is fully elevated, then
release switch.
• Display reads PLEASE LOWER.
11. Hold switch in down position until platform is in the fully lowered position. Release
switch.
• Display reads FINISHED.
CE C
ALIBRATIONS
CE Platform Load Calibration
Perform the tilt sensor calibration outlined at the beginning of this section (" ANSI/CE
Tilt Sensor Calibration" on page 2-20).
Platform Load calibration must be performed any time:
• significant repairs are made to the elevating assembly
• the lift cylinder is removed and serviced or replaced
• any Platform Overload System component is replaced
During the calibration procedure the platform is fully raised and lowered three times:
1. “DYNAMIC” calibration – fully loaded platform raised & lowered in one continuous
movement. DYNAMIC measurements are taken.
2. “LOADED” calibration – fully loaded platform raised & lowered with stops to take
measurements. STATIC measurements are taken.
3. “EMPTY” calibration – unloaded platform raised & lowered with stops to take mea-
surements. STATIC measurements are taken.
The following procedure must be followed COMPLETELY to calibrate the GP400 Over-
load System. If any problem is detected, the procedure stops and an Error Message will
display on the EZ-Cal. Explanations of each message and suggested corrections can be
found in the section of this manual following the calibration procedure.
NOTE:
If the calibration procedure is interrupted, completed phases do not need to be repeated. A “REDO” prompt
will appear – answer “NO” if there is no reason to repeat the phase, or “YES” if the phase must be repeated (for
example because the wrong platform load was used on the previous phase).
1. Drive machine to a flat, level surface where it can reach full elevation. Choose a place
where the rated load can be placed in the platform and later removed without moving
the machine.
2. Place rated load in platform (see platform labels or serial plate).
3. Turn selector switch to Base controls.
4. Plug EZ-Cal into connector P9 on GP400 Control Module. EZ-Cal display reads
HELP: PRESS ENTER
5. Press right arrow to ACCESS LEVEL 3, Press Enter.
• Display reads CODE 0000
6. Press up and right arrow to enter code 2222, Press Enter.
• Display reads ACCESS LEVEL 2.
• On later models, the display may continue to read “ACCESS LEVEL 3”. Repeat step b. and
enter code 1775.
Содержание Speed Level 2684 ES
Страница 52: ...3084 Speed Level Sigma Lift Service and Parts Manual October 2009 Page 1 32 GENERATOR OPTION 3084RT NOTES...
Страница 104: ...3084 Speed Level Sigma Lift Service and Parts Manual November 2009 Page 3 20 ENGINE MAINTENANCE NOTES...
Страница 142: ...3084 Speed Level Sigma Lift Service and Parts Manual November 2009 Page 4a 38 TROUBLESHOOTING 3084RT MODELS NOTES...