CSP–900RFM206E–1
ROTORCRAFT FLIGHT MANUAL
MD900 With PW 206E
Handling Servicing
and Maintenance
Original
8–28
Main Transmission Filling
Open access panel (Ref. Figure 8−6 and Figure 8−7).
Open oil filler cap (Ref. Figure 8−17).
Pour in oil.
Verify quantity of oil in sight window.
Close oil filler cap.
Close access panel (Ref. Figure 8−6 and Figure 8−7).
Main Transmission Draining
Open access panel (Ref. Figure 8−6 and Figure 8−7).
Remove chip detector (Ref. RMM, Section 63−20−00).
Using transmission drain line, place free end of drain line in a suitable container.
Insert drain line probe in chip detector housing.
Allow transmission to drain.
Remove drain line and install chip detector (Ref. RMM, Section 63−20−00).
Close access panel (Ref. Figure 8−6 and Figure 8−7).