CSP–900RFM206E–1
Emergency and
Malfunction Procedures
ROTORCRAFT FLIGHT MANUAL
MD900 With PW 206E
FAA Approved
Original
3–11
Indications:
Inability to change engine mode with engine control switch.
Conditions:
In flight
Procedures:
F
Continue flight
F
After landing, perform manual engine shutdown (Ref. paragraph 3−7).
Conditions:
On ground
Procedures:
F
Perform manual engine shutdown (Ref. paragraph 3−7).
Indications:
N
P
and N
R
indications not matched (split)
Conditions:
In flight
Procedures:
F
Continue flight
F
Avoid maneuvers that cause N
R
to increase above normal. (High rates of de
scent, quick stops)
Conditions:
On ground
Procedures:
F
Do not takeoff
F
Advise maintenance