CSP–900RFM206E–1
Emergency and
Malfunction Procedures
ROTORCRAFT FLIGHT MANUAL
MD900 With PW 206E
FAA Approved
Original
3–37
BATTERY WARM
Indications:
Yellow BAT WRM annunciator ON (battery internal temperature 57
°
C).
Conditions:
On ground
Do not attempt to start an engine on battery power with BAT WRM
annunciator ON.
NOTE
:
A battery warm condition results in the battery being disconnected from the
aircraft electrical system once a generator is placed on line. Generator power
alone is not sufficient to start an engine.
Procedures:
F
Utilize a GPU to start engines.
F
Power switch OFF after both generators are on line.
F
If BAT WRM annunciator remains ON for more than five minutes, shutdown
the aircraft.
F
Otherwise, continue flight.
F
Service or replace battery prior to next flight.
Conditions:
In flight
Procedures:
F
Power switch OFF.
F
Continue flight.
F
Service or replace battery prior to next flight.
CAUTION