Overview
2 - 21
Talon 2000 Interface
Stopwatch
Stopwatch to time the different phases of the fusion process.
There is a pause/start button and a reset button.
.
Carriage Displacement
Displays the displacement of the fusion carriage. This could be
used to determine bead-up displacement.
Program Status Messages
Displays status and errors of components during operation.
Machine Controls
Opens the Machine Control screen.
Heater Settings
Opens the Heater Settings screen.
Indexer Settings
Opens the Indexer Settings screen.
Heater Temperature Settings
Opens the Heater Temperature Settings screen.
Stop Fusion
Stops the fusion, resets all parameters and opens the Manual
Facing screen.
.
Pressure Selection
3 position selector for hydraulic pressure for Facing, Heating
and Fusing.
Carriage Valve Selector
5 position selector for opening and closing the carriage.
The positions are open and close with neutral in the middle.
Between open/close and neutral is a momentary movement
position.
Pressure Adjustments
3 pressure adjustors for Facing, Heating and Fusing pressures.
Touch the adjustor to bring up a keypad to enter the pressure
value or close the keypad and use the up and down arrows
to adjust the selected pressure. Holding the arrow will
continuously adjust the pressure.
Component Fault
This button will appear over or near a component that has a fault with
the component. Touch the button to open the screen to correct the fault.
Heater Elevation Tensioner Fault
This button will appear over the Heater Up/Down buttons and indicates
a fault with the tension of the heater chain tensioners.
Heater Element Failure
This button will appear over the Heater graphic and indicates a heater
element failure or incorrect wiring.
Fusion Button
Automates the opening of the carriage, retracts the heater then closes
the carriage.