4 - 5
Operation
DataLogger Operation
Machine Information
The machine information is displayed on this screen. The fusion specification used for the fusion process is selected on this screen.
The interfacial pressure according to the selected fusion standard is displayed at the bottom of the screen.
Å
TEPA:
The total effective piston area for the machine is displayed.
Å
Machine ID:
The machine ID is displayed.
Å
Fusion Type:
The type of fusion is displayed.
Å
Machine Model:
The model of the fusion machine is displayed.
Å
Specification:
Select the fusion standard to be used from a list of pre-loaded fusion standards.
Å
Interfacial Pressure:
Displays the interfacial pressure range used for the selected fusion standard. The operator can
type in a specific interfacial pressure that is within the range of the fusion standard interfacial
pressure.
Press
Next
to go to the next screen.
Press
Back
to go to the previous screen.
PH053
94-0
4-1
5-1