Talon 2000 Fusion Machine
INSPECTION CHECKLIST
1. Machine is clean
2. Hydraulic oil is visible in reservoir sight glass
3. Hydraulic hoses are in good condition
4. Hydraulic carriage works smoothly
5. All hydraulic cylinders adjusted (speed and travel)
6. All grease points and pivot points lubricated
7. No visual oil leaks (hydraulic system)
8. All identification placards are on unit
9. Wiring & all electrical terminals are in good condition
10. Jaws are aligned properly
11. Inserts fit and mounted properly
12. Facer works properly
13. Heater in good condition (no nicks or gouges)
14. Surface temperature check with a pyrometer
15. Switches and buttons work properly
16. HMI and software working properly
17. All hardware is with unit (inserts and pins, etc.)
18. System pressure (3000 psi)
19. Power cords and plugs in good condition
20. All rest buttons in place
21. Stripper cylinder work properly
22. No damage to fusion machine
23. Inspect lifting points for damage.
24. Lifting slings are not damaged and are in good condition
25. Quarter jaws are not damaged and mounted properly
Maintenance Checklist
10 - 1
TX05038-05-03-16