Operation
4 - 10
DataLogger Operation
Å
Lower the facer.
Å
Shut off the fusion machine.
Hydraulically operated equipment is operated under
pressure. Anything caught in the machine will be
crushed. Keep fingers, feet, arms, legs, and head out of
the machine while operated.
Å
Visually inspect the pipe ends for a smooth cut appearance. Clear any pipe shaving from the inside of the pipe. Deburr the pipe
ends.
NOTICE:
Remove shavings that pose a risk of contamination. If using a vacuum, use caution while vacuuming close to the ground
so not to introduce dirt/dust onto the pipe ends.
IMPORTANT:
A tarp can be used under the fusion area to remove shavings.
Inside of pipe is slippery and you could fall resulting in
minor to moderate injury. Use caution by using arms to
balance while moving inside the pipe.
NOTICE:
Do not touch the ends of the pipe. Contamination of the pipe ends could effect the fusion joint.
Å
Restart the machine and log into the application. Touch DataLogger operation and then the return button to go back to the last
screen in the operation.
Å
Fully raise the facer.
Press
Next
to go to the next screen.
Press
Back
to go to the previous screen.
¡PRECAUCIÓN!
ОСТОРОЖНО
ATTENTION
¡ADVERTENCIA!