89
For Machines Equipped with Taylor's
Remote Monitoring System
FCC/IC ID Label Placement:
•
This hardware installation package includes a label
that must be placed on the machine immediately
after the installation of the hardware device has been
completed.
•
The label indicates the FCC ID and Industry Canada
ID for the wireless communication device. The label
must be placed on the outside surface of the
machine, in a manner that is visible and
unobstructed.
•
It is recommended that this label be placed directly
adjacent to the product nameplate of this device.
FCC Compliance Statement:
•
This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules.
•
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial environment.
•
This equipment generates, uses, and can radiate
radio frequency energy, and if not installed and used
in accordance with the instruction manual, may
cause harmful interference to radio communications.
•
Operation of this equipment in a residential area is
likely to cause harmful interference, in which case
the user will be required to correct the interference at
his own expense.
Industry Canada Statement:
•
This device complies with Industry Canada
license-exempt RSS standard(s).
•
Operation is subject to the following two conditions:
a. This device may not cause interference.
b. This device must accept any interference,
including interference that may cause undesired
operation of this device.
Dispensing Shake Without Syrup
Beginning with software version 1.04, shakes can be
dispensed without flavoring by selecting the left-side Mix
Pump symbol
Figure-247
The following screen will display. (See Figure-248.)
Figure-248
Select the Calibrate symbol
. The left-side Mix Pump
symbol illuminates and unflavored product immediately
starts to dispense. The unflavored draw ends and the Mix
Pump light extinguishes when the pyroelectric sensor
detects the cup is full. The unflavored draw can also be
terminated by selecting the Mix Pump symbol
a
second time.
Note:
To cancel the UNFLAVORED DRAW screen,
press the optional Flavor symbol
to move the arrow to
NO and select the Calibrate symbol
.
Содержание C602
Страница 2: ......
Страница 7: ...5 C602 Exploded View Figure 1 23 12 11 10 9 22 7 6 5 4 1 1a 3 1a 8 21 19 14 18 16 15 17 13 20 8 2 ...
Страница 9: ...7 Front View Figure 2 1 2 3 4 5 7 7a 10 11 8 8 9 7c 7b 6 12 13 14 ...
Страница 13: ...11 X57028 XX Pump A Mix Simplified Shake Figure 5 13 8 8 12 9 7 6 4 2 5 4 1 11 10c 10a 10b 14 3 10d 10 ...
Страница 15: ...13 X57029 XX Pump A Mix Simplified Soft Serve Figure 6 4 2 11 10d 10c 14 10b 10a 1 4 8 8 13 12 9 7 6 5 10 3 ...
Страница 21: ...19 Beater Door Assembly Shake Side Figure 11 6 4 1 3 2 5 17 11 13 12 7 8 10 9 14 15 16 ...
Страница 23: ...21 Beater Door Assembly Soft Serve Side Figure 12 2 3 11 4 5 12 13 1 14 15 16 6 8 7 6 9 10 ...
Страница 25: ...23 X53800 BRN TAN Syrup Pump Figure 13 3 4 2g 5 1 2e 2f 2d 2c 2a 2b 2 2h ...
Страница 114: ...057888 M ...