104
Too much syrup
flavoring in shake.
a. Improper syrup
calibration caused
by using incorrect
syrup calibration
cup.
a. Use correct calibration cup (Taylor part no. 017203) and
use the small chamber of the cup.
b. Incorrect syrup
dispensing rate
caused by not
calibrating syrup
flavor.
b. Calibrate weekly or as needed. Non-TTS syrup calibration
is: 1 oz. (30 ml) ± 1/4 oz. (7 ml) in 5 seconds. Triple thick
shake syrup calibration is: 1 oz. (30 ml) ± 1/8 oz. (4 ml) in
7 seconds.
c. Incorrect shake
dispensing rate.
c. A 16 oz. triple thick shake should dispense in 7 to 8
seconds. If draw time is longer, inspect the mix pump for
blockage or worn seals.
Problem
Shake Side
Probable Cause
Soft Serve Side
Probable Cause.
Either Side Probable
Cause
Corrective Action