97
Shake draw valve is
not opening.
a. The power switch
is OFF.
a. Place the power switch in the ON position.
b. The shake side is
in the Standby
mode.
b. Cancel the Standby mode.
c. A Heat cycle is in
progress.
c. Wait for the completion of the Heat Treatment cycle.
d. The menu is
displayed, making
the flavor select
keys inoperative.
d. Exit the menu to restore the control keys to their normal
function.
e. The draw valve
wasn't aligned with
the actuator
bracket when the
freezer door was
installed.
e. Reassemble with the correct alignment. Tighten the
handscrews in a crisscross pattern when installing the
freezer door.
f. The draw valve
was not lubricated.
f. Lubricate the draw valve and O-rings.
g. The shake actuator
assembly is out of
alignment or is
malfunctioning.
g. Call a service technician.
Problem
Shake Side
Probable Cause
Soft Serve Side
Probable Cause.
Either Side Probable
Cause
Corrective Action
Содержание C602
Страница 2: ......
Страница 7: ...5 C602 Exploded View Figure 1 23 12 11 10 9 22 7 6 5 4 1 1a 3 1a 8 21 19 14 18 16 15 17 13 20 8 2 ...
Страница 9: ...7 Front View Figure 2 1 2 3 4 5 7 7a 10 11 8 8 9 7c 7b 6 12 13 14 ...
Страница 13: ...11 X57028 XX Pump A Mix Simplified Shake Figure 5 13 8 8 12 9 7 6 4 2 5 4 1 11 10c 10a 10b 14 3 10d 10 ...
Страница 15: ...13 X57029 XX Pump A Mix Simplified Soft Serve Figure 6 4 2 11 10d 10c 14 10b 10a 1 4 8 8 13 12 9 7 6 5 10 3 ...
Страница 21: ...19 Beater Door Assembly Shake Side Figure 11 6 4 1 3 2 5 17 11 13 12 7 8 10 9 14 15 16 ...
Страница 23: ...21 Beater Door Assembly Soft Serve Side Figure 12 2 3 11 4 5 12 13 1 14 15 16 6 8 7 6 9 10 ...
Страница 25: ...23 X53800 BRN TAN Syrup Pump Figure 13 3 4 2g 5 1 2e 2f 2d 2c 2a 2b 2 2h ...
Страница 114: ...057888 M ...