102
Shake not filling
completely to top line
in cup.
a. Cup improperly
placed in holder,
causing fill sensor
to activate at lower
level in cup.
a. Place the cup in the holder with the lip resting on the clips.
b. Cup holder clips
improperly
installed.
b. Properly install the clips in the cup holder.
c. Fill level
adjustment screw
is set low.
c. Adjust to a higher position by turning the screw
counterclockwise.
d. Shake is stacking
in center of cup.
d. Check the syrup calibration and shake temperature.
e. Wrong cup was
used.
e. Use McCafe Shake cups only.
f. Sensor shield is
damaged.
f. Replace the sensor shield.
g. Draw valve closes
before reaching fill
sensor; defective
fill sensor.
g. Call a service technician.
Problem
Shake Side
Probable Cause
Soft Serve Side
Probable Cause.
Either Side Probable
Cause
Corrective Action
Содержание C602
Страница 2: ......
Страница 7: ...5 C602 Exploded View Figure 1 23 12 11 10 9 22 7 6 5 4 1 1a 3 1a 8 21 19 14 18 16 15 17 13 20 8 2 ...
Страница 9: ...7 Front View Figure 2 1 2 3 4 5 7 7a 10 11 8 8 9 7c 7b 6 12 13 14 ...
Страница 13: ...11 X57028 XX Pump A Mix Simplified Shake Figure 5 13 8 8 12 9 7 6 4 2 5 4 1 11 10c 10a 10b 14 3 10d 10 ...
Страница 15: ...13 X57029 XX Pump A Mix Simplified Soft Serve Figure 6 4 2 11 10d 10c 14 10b 10a 1 4 8 8 13 12 9 7 6 5 10 3 ...
Страница 21: ...19 Beater Door Assembly Shake Side Figure 11 6 4 1 3 2 5 17 11 13 12 7 8 10 9 14 15 16 ...
Страница 23: ...21 Beater Door Assembly Soft Serve Side Figure 12 2 3 11 4 5 12 13 1 14 15 16 6 8 7 6 9 10 ...
Страница 25: ...23 X53800 BRN TAN Syrup Pump Figure 13 3 4 2g 5 1 2e 2f 2d 2c 2a 2b 2 2h ...
Страница 114: ...057888 M ...