GENERATOR
1. Adjusting bolt
2. Generator
3. Pivot bolt
4. “B” terminal wire
5. Coupler
6. Nut
: Tightening Torque
REMOVAL
1) Disconnect negative cable (1) at battery (2).
2) Remove front bumper.
3) Disconnect “B” terminal wire (3) and coupler (4) from generator
(5).
4) Remove adjusting bolt (1) and pivot bolts (2).
5) Remove generator.
INSTALLATION
Reverse above procedure giving specified tension to drive belt.
Refer to “Generator (Water Pump) Belt” for belt tension.
Tightening Torque
(a): 22 N·m (2.2 kg-m, 16.0 lb-ft)
(b): 50 N·m (5.0 kg-m, 36.5 lb-ft)
(c): 7 N·m (0.7 kg-m, 5.0 lb-ft)