3-32
3-32
F2 - AIR CONDITIONING (OPTION)
F2 - AIR CONDITIONING (OPTION)
CLEANING – INSPECTION
CLEANING – INSPECTION
CLEANING CONDENSER AND EVAPORATOR COILS (*)
CLEANING CONDENSER AND EVAPORATOR COILS (*)
CLEANING CONDENSATE TRAY AND RELIEF VALVE (*)
CLEANING CONDENSATE TRAY AND RELIEF VALVE (*)
COLLECTING COOLANT TO REPLACE FILTER-DRIER (*)
COLLECTING COOLANT TO REPLACE FILTER-DRIER (*)
REFILLING WITH COOLANT AND CHECKING THE THERMOSTATIC CONTROL AND PRESSURE SWITCHES (*)
REFILLING WITH COOLANT AND CHECKING THE THERMOSTATIC CONTROL AND PRESSURE SWITCHES (*)
NOTE: When opening the evaporator unit, r
NOTE: When opening the evaporator unit, r
emember to replace the cover seal.
emember to replace the cover seal.
(*): (CONSULT YOUR DEALER).
(*): (CONSULT YOUR DEALER).
CAUTION: DO NOT
CAUTION: DO NOT
ATT
ATT
EMPT TO REPAIR ANY PROBLEMS
EMPT TO REPAIR ANY PROBLEMS
YOURSELF
YOURSELF
. ALWA
. ALWA
YS REFER TO
YS REFER TO
YOUR DEALER WHEN
YOUR DEALER WHEN
REFILLING CIRCUITS, AS THEY HOLD
REFILLING CIRCUITS, AS THEY HOLD
THE
THE
CORRECT SPARE PARTS, AS WELL AS HAVING THE NECESSARY TECHNICAL KNOWLEDGE AND TOOLS.
CORRECT SPARE PARTS, AS WELL AS HAVING THE NECESSARY TECHNICAL KNOWLEDGE AND TOOLS.
- Do not open the circuit under any circumstances as this would cause the coolant to be lost.
- Do not open the circuit under any circumstances as this would cause the coolant to be lost.
-
-
The cooling circuit contains a gas which ca
The cooling circuit contains a gas which ca
n be dangerous under certain conditions. This gas, coolant R
n be dangerous under certain conditions. This gas, coolant R
134a, is colourless,
134a, is colourless,
odourless and heavier than air.
odourless and heavier than air.
• If this gas is
• If this gas is
inhaled, take the victim into fresh air, give oxygen or ar
inhaled, take the victim into fresh air, give oxygen or ar
tificial respiration if necessary and call a
tificial respiration if necessary and call a
doctor
doctor
.
.
• If the gas is
• If the gas is
in contact with the skin, wash it
in contact with the skin, wash it
immediately under running water and remove any contaminated garments.
immediately under running water and remove any contaminated garments.
• If the gas is
• If the gas is
in contact with the eyes, rinse them in
in contact with the eyes, rinse them in
clear water for 15 minutes and call a
clear water for 15 minutes and call a
doctor
doctor
.
.
-
-
The compressor has an oil level gauge (f
The compressor has an oil level gauge (f
ig. F2). Never unscrew this gauge b
ig. F2). Never unscrew this gauge b
ecause it
ecause it
would depressurizes the installation. The oil level is only checked when changing the oil
would depressurizes the installation. The oil level is only checked when changing the oil
in the circuit.
in the circuit.
F2
F2
https://www.forkliftpdfmanuals.com/
Содержание MLT 845 120 LSU 3-E3 Series
Страница 2: ...https www forkliftpdfmanuals com...
Страница 4: ...https www forkliftpdfmanuals com...
Страница 6: ...1 2 1 2 https www forkliftpdfmanuals com...
Страница 27: ...1 22 1 22 https www forkliftpdfmanuals com...
Страница 32: ...1 27 1 27 https www forkliftpdfmanuals com...
Страница 33: ...1 28 1 28 2 2 DESCRIPTION DESCRIPTION https www forkliftpdfmanuals com...
Страница 34: ...2 1 2 1 https www forkliftpdfmanuals com...
Страница 64: ...2 31 2 31 39 TOOL BOX 39 TOOL BOX https www forkliftpdfmanuals com...
Страница 65: ...2 32 2 32 https www forkliftpdfmanuals com...
Страница 74: ...2 41 2 41 https www forkliftpdfmanuals com...
Страница 75: ...2 42 2 42 3 3 MAINTENANCE MAINTENANCE https www forkliftpdfmanuals com...
Страница 76: ...3 1 3 1 https www forkliftpdfmanuals com...
Страница 87: ...3 12 3 12 https www forkliftpdfmanuals com...
Страница 97: ...3 22 3 22 https www forkliftpdfmanuals com...
Страница 112: ...4 1 4 1 https www forkliftpdfmanuals com...
Страница 114: ...4 3 4 3 https www forkliftpdfmanuals com...