77
Control unit MGC mTripod
Corrective action
Number
Designation
Possible cause
Corrective action
FF32
ERROR
HW-Enable test failed
–
›
Check position and
attachment of the control
unit MGC (circuit board). If
necessary, correct position
and reattach.
›
Perform reset.
›
Perform software update.
Table 35:
Event, warning and error messages – Motor MHP2
8.6.3
Event, Warning and Error Messages – Motor GW
Follow the troubleshooting below for mTripod pedestrian gates with an MHP1
motor.
Number
Designation
Possible cause
Corrective action
2220
WARNING
Over current
Over current detected
Warning may occur in
connection with an
impact.
›
If no impact has occurred,
check the wiring.
›
If required, contact
Service.
3211
WARNING
Over voltage
Over voltage detected
Warning may occur in
connection with an
impact.
›
If no impact has occurred,
check the wiring.
›
If required, contact
Service.
3221
WARNING
Under voltage
Under voltage detected
The message may
appear if the blocking
element is held and
pressed for a longer
period of time while the
holding torque is active.
›
Check the hold time by
pressing on the blocking
element while the passage
is blocked. If the hold time
is shorter than 1s, replace
the mains unit.
›
Disconnect additional
loads from the MGC
control unit.
4210
WARNING
Over temperature
High temperature
detected.
›
Check the motor
temperature via the
"Motor GW" menu. The
temperature must be
below 100°C.
›
If required, contact
Service.