Description of menus and parameters
Operational view > Main menu > Settings > Random check function
Parameter
Description
Count of hits
Set the number of hits to be generated in the set Count of hits.
IMPORTANT! The value for the "Count of hits" parameter can be a maximum
of 40 % of the value for the "Hit range" parameter. If the value set for the
"Hit range" parameter is too high, the "Hit range" parameter is automatically
adjusted.
Setting range
›
1 to 1000
Factory setting
›
10
Delete validation
Use the "Delete validation" parameter to specify whether the validation is to
be deleted automatically in the event of a random hit.
Options
›
Activated [ X ]
Select this option if you want the check to take place before the passage.
The user leaves the area via a separate passage.
›
Deactivated [ ]
Select this option if you want the passage to take place when the hit is
confirmed. In this case, the check is carried out after the passage.
Factory setting
›
Deactivated [ ]
Direction
Select the passage direction for which the random hits are to be generated.
Options
›
Both: Random hits occur in both passage directions. With this option,
validations are not deleted.
›
Left: Random hits occur only for the "left" passage direction.
›
Right: Random hits occur only in the "right" passage direction.
Factory setting
›
Both
Table 26:
Random check function