45
Control unit MGC mTripod
Description of menus and parameters
6
Description of menus and parameters
6.1
"Information" menu
Accessing and navigating
The operational view is displayed.
1. Press left button « ».
2. Use the left button « » to scroll within the menu.
3. The "Information" menu can be left as follows:
›
press the left button « » repeatedly until the operational view is
displayed again or
›
press the right button « ».
Operational View > Information
Parameter
Description
Error, warning or
event messages
Display of the error, warning or event messages that occurred since the last
voltage reset, including date and time.
Use the
« » and « »
buttons to navigate through the messages.
If no messages are present, the menu is not displayed.
Inputs
Displays the current settings for the digital inputs IN1 to IN8.
Separate inputs can be deactivated or inverted. Deactivated inputs are
marked with a "–", e.g. "IN8: –". Inputs with inverted functions are marked
with a "|", e.g. "IN7: | Illumination off".
Outputs
Displays the current settings for the digital outputs DO1 to DO4 and the relay
outputs NO1 to NO3 and NO/NC4 to NO/NC6.
Separate outputs can be deactivated or inverted. Deactivated outputs are
marked with a "–", e.g. "DO2: –". Outputs with inverted functions are
marked with a "|", e.g. "NO5/NC5: | Passage clear right".
Module info
Display of the software numbers (software #) and software versions (SW
version) of the control unit and plugged-in plug-in modules.