27
Control unit MGC mTripod
Description of the "MGC.Connect" programme
The view offers the following options.
Information about the input functions:
Button /
parameters
Description
The permanent signal is deactivated.
The 3 central buttons simulate pulse operation and you can test the
respective input function by clicking on the button. The selected
input function is automatically reset.
The permanent signal is activated.
The 3 central buttons are in hold mode. After you have selected an
input function, this input function is held until you click the button
again.
Test input function "Open from left".
Trigger a validation from left. A passage from left is possible.
Test input function "Inhibit opening".
Lock the pedestrian gate in both passage directions and delete
validations. No opening signals are accepted anymore.
Test input function "Open from right".
Trigger a validation from right. A passage from right is possible.
Test input function "Emergency open".
Validations
Display of pending validations.
Hold-open time
Display of the current hold-open time still available.
If several validations are pending, the total hold-open time is not
displayed. The hold-open time is counted down again from the set
value with each validation.
Passage counter Display of the current counters.
Random check
function
Activate and test the "Random check function" function.
Table 11:
"Passage control" tab – Description buttons and parameters