31
Control unit MGC mTripod
Description of the "MGC.Connect" programme
1. Click the "Closed (0°)" button.
√
The motor is de-energised.
√
The Settings mode is activated and is signalled as follows:
In the "MGC.Connect" programme, status display, below the product
image, the bar flashes yellow. The optional frame illumination also
flashes yellow.
2. Move the blocking element to the desired "Closed" position.
√
After 5 seconds, the new position is accepted as the "Closed (0°)"
position. The position corresponds to 0°.
√
The mTripod pedestrian gate automatically switches to normal
operation. If a buzzer is installed, a short tone will sound.
√
The "Closed" position is aligned.
4.6.2
Description of the buttons and parameters
Button /
parameters
Description
Align positions
Set position "Closed (0°)". The set position "Closed (0°)"
corresponds to 0°. After you have clicked the button, you have
10 seconds to move the blocking element. The remaining time is
displayed in the "Align positions" section.
Experte -
Deactivate motor
Disconnect the motor from mains. You can move the blocking
element freely and check the current position of the blocking
element in the status display. The "Closed" position is 0°.
Experte -
Reset MGC
Perform reset.
System report
Open the current system report. You can save the system report.
The system report includes various information, the current
parameterisation of the inputs and outputs, an event list (event log)
and the current parameter settings.
Date/Time
Set the date and time.
Information
Display of serial number, software # and software versions
Operating cycles Display of the current cycle counter reading of the pedestrian gate.
The counter reading cannot be changed.
Operating time
Displays the operating hours counter. The operating hours counter
records the time, during which the pedestrian gate is supplied with
electrical power.
Table 16:
"Service" tab – Description buttons and parameters
Содержание mTripod
Страница 86: ...86 Control unit MGC mTripod...
Страница 90: ...90 Control unit MGC mTripod...
Страница 91: ...91 Control unit MGC mTripod...