Control unit MGC mTripod
Function description
7.4.2
Pulse operation in one direction / permanent open in the other
direction
Prerequisite: For the parameter "Permanent open" either the option "After
3 s" or "After 10 s" has been selected.
"
Permanent open
" parameter:
When a permanent signal is present on one of the two inputs "Open from left"
and "Open from right", passage is cleared in the corresponding direction. Pulse
operation remains active in the other direction.
If a validation is given for the passage direction in pulse operation, it is still
possible to pass the pedestrian gate in the permanent open direction. After a
successful passage, the hold-open time for the validation is set again in pulse
operation.
After removal of the permanent signal, the corresponding direction is locked at
once without completion of the hold-open time.
7.4.3
Permanent clearance in both directions
Prerequisite: For the parameter "permanent open" either the option "After
3 s" or "After 10 s" has been selected.
If a permanent signal is present at the two "Open from left" and "Open from
right", the control unit switches to the "Permanent open" operating mode for
both directions. This means that the passage is enabled in both directions and
no validation must be given.