74
Control unit MGC mTripod
Corrective action
Number
Designation
Possible cause
Corrective action
6110
ERROR
Safety Controller: SW
update required
MHP2 motor detected.
A software package with
the firmware Motor GW
is installed in the control
unit.
Perform the software update
as follows:
›
Execute package PREPARE_
MHP2.
›
Install the latest firmware
package for pedestrian
gates SMP-MGC-PA0.
6111
ERROR
Motor GW: SW update
required
No motor detected.
Firmware Motor GW is
required for the
selected product.
›
Check setting for gate
type.
Perform the software update
as follows:
›
Execute package PREPARE_
MHP1.
›
Install the latest firmware
package for pedestrian
gates SMP-MGC-PA0.
6130
ERROR
Safety Controller:
Configuration faulty
The configuration of the
safety controller is not
consistent.
›
Reset parameters to
factory settings.
7530
WARNING
Motor MPH2:
Communication faulty
›
No motor connected.
›
Cables and / or plugs
to the motor
interrupted.
›
Power supply to the
motor interrupted.
›
Check connections.
›
Check CAN termination
and correct if necessary.
See separate electrical
wiring diagram.
8130
WARNING
Node monitoring
The communication to a
plug-in module was
interrupted.
›
Check whether all plug-in
modules are listed in the
main menu.
›
Perform reset.
FF20
WARNING
Emergency open active 0 V or no signal is
present at the
"Emergency open"
input.
›
Check input signal.
›
If not used, deactivate the
input function.
FF21
WARNING
Max. pulses without
passage reached
The set maximum
number of pulses
without passage has
been reached.
›
Check card reader /
validation device, e.g. card
reader.
›
Check the "Max pulse w/o
passage" parameter.
Содержание mTripod