363-205-401
DT Turn Up: NTP-003
Issue 7, March 1997
Page 3 of 4
DO ITEMS BELOW IN ORDER LISTED
FOR DETAILS, GO TO
4.
Connect power to DT
A. At AC outlet box, insert 900A1 DT power plug into AC outlet.
B. At pedestal DC power interface, connect 900A2 or 900A3
DT power cord and customer DC power feed pair if not
already done.
5.
NOTE:
Do not connect J104 to the batteries at this time.
Install 900A1, 900A2, or 900A3 DT batteries in tray in bottom of
DT closure.
6.
Install ASH1 PCU.
7.
If required, install EAF1 drop test module on ASJ2 channel unit.
8.
Install ASJ1 or ASJ2 channel unit and secure.
9.
NOTE:
If electrical connector J105 is not connected to P105 on the
AYB1B optical unit backplane, make the connection at this
time. When making the connection verify that the top of the
J105 connector (labeled TOP) is oriented properly.
Install AYB1B optical unit.
10. Power up DT.
11. Measure voltages at ASH1 PCU faceplate.
12. Close and lock the AC outlet box. (900A1 DT only)
13. Close and lock the 900A1, 900A2, or 900A3 DT closure unless
end-to-end tests are to be performed at this time. Close pedestal
or DT enclosure if necessary.
14. Update office records.