10. Does test set fan operate?
If YES, then proceed to Step 15.
If NO, then proceed to Step 35.
11. On test set connector head, remove battery lead and check for blown fuse(s).
12. Is fuse(s) blown?
If YES, then continue with Step 13.
If NO, then proceed to Step 14.
13. Replace fuse(s) and repeat from Step 5.
14.
NOTE:
Test set may be used for testing using one, two, three or all four BATT
plug positions.
Defective test set or connector head. Note defective BATT plug position(s).
Continue with test procedures using remaining BATT plugs.
15. Does test set TIME display indicate 00 MIN:00 SEC without blinking?
If YES, then continue with Step 16.
If NO, then proceed to Step 35.
16. Does status display indicate which battery was connected, status (GOOD or
REPLACE) of the battery, and is READY indicator lighted?
If YES, then continue with Step 17.
If NO, then proceed to Step 35.
17. Does status display indicate GOOD or REPLACE?
If YES, then proceed to Step 19.
If NO, then continue with Step 18.