RT Turn Up: DLP-506
363-205-401
Page 4 of 8
Issue 7, March 1997
!
CAUTION:
FPB Mode 2 must be set to NC for ADU FAIL, MN, NE, and CMP alarms
to clear.
• 4 - Toward DBL.
• 5 - Toward NPA.
• 6 - Toward MNP.
• 7 and 8 - Unused.
6.
Set switch S3 toward DL.
7.
Set system identification rotary switches S4 (most significant digit) through S7
(least significant digit) to bank ID number.
8.
Set rotary switches S8 through S11 to 0.
9.
NOTE:
The NORM/CLEAR switch option is used to automatically clear random
channel provisioning data stored in the ADU and BCU when the BCU is
installed by selecting CLEAR. After the BCU has been installed, the
NORM position is used.
Set NORM/CLEAR option plug for CLEAR option (center and bottom pins).
10.
!
CAUTION:
Incorrectly set ADU option switches may result in immediate or future
loss of service or may introduce errors into the digital bitstream.
Insert ADU into lower ADU slot if equipping blue bank or upper ADU slot if
equipping white bank.
Response:
Disregard all indicators that may be lighted.
11.
NOTE:
When the BCU is first installed, the ADU should be set for preservice and
unequipped digroups (AB and CD) to verify these units (ADU and BCU)
are functioning properly (all alarms clear).
Install BCU.
Reference:
DLP-508