RT Turn Up: NTP-006
363-205-401
Page 2 of 6
Issue 7, March 1997
DO ITEMS BELOW IN ORDER LISTED
FOR DETAILS, GO TO
2.
Verify the following:
• The outside cable pairs are not connected through to the
remote terminal (RT) so that the RT is isolated from the digi-
tal and derived lines.
• The frame or cabinet housing the RT has been installed.
The J1C182AB, J1C182AC, J1C182AE, J1C182AF, or
J1C182AH dual channel bank assembly has been installed in
the frame or cabinet enclosure.
• The miscellaneous pair panel, protector connectors, power
shelf, fan shelves, and battery shelves (if required) have
been installed in the frame or cabinet enclosure.
• The acceptance procedures in this volume have been per-
formed.
• The cabinet or frame supporting equipment has been turned
up using procedures in this volume.
3.
!
CAUTION:
An electrostatic discharge wrist strap with a minimum
resistance of 250K Ohms should be worn when handling
Series 5 circuit packs to prevent possible damage to the
circuit packs. Before using the wrist strap, check it for
opens, shorts, and minimum resistance value. If the strap
does not pass these checks it should not be used. To avoid
possible personal injury while using the wrist strap, do not
connect it to the power shelf or adjacent portions of the RT
frame. Connect the wrist strap to ESD GRD jack on the fan
unit, if present. If grounding jack is not present, connect
wrist strap to bare-metal section of the frame well away from
the power shelf.
Remove 3-type voltage protector units in protector panel forthe
DS1s being equipped.
DLP-521
4.
Verify, per work order, that the correct complement of circuit
packs is available.