![LSIS G100 Скачать руководство пользователя страница 92](http://html.mh-extra.com/html/lsis/g100/g100_operation-manual_1944296092.webp)
Acc/Dec Time Based on Operation Frequency
– Setting Details
Code and
Features
Description
bA.08
Ramp T Mode
Set the parameter value to 1 (Delta Freq) to set Acc/Dec times based
on Maximum frequency.
Configuration
Function
0
Max Freq
Set the Acc/Dec time based on maximum
frequency.
1
Delta Freq
Set the Acc/Dec time based on operating
frequency.
If Acc/Dec times are set to 5 seconds, and multiple frequency
references are used in the operation in 2 steps, at 10 Hz and 30 Hz, the
time to accelerate will be as follows.
4.8.3 Multi-step Acc/Dec Time Configuration
Acc/Dec times can be configured via a multi-function terminal by setting the ACC
(acceleration time) and dEC (deceleration time) codes in the Operation group.
Group
Code
Name
Setting
Setting Range
Unit
Operatio
n
ACC
Acceleration time 5.0
0.0
–600.0
sec
dEC
Deceleration time 10.0
0.0
–600.0
sec
bA
70
–82
Multi-step
acceleration time
1
–7
0.0
0.0
–600.0
sec
71
–83
Multi-step
deceleration time
1
–7
0.0
0.0
–600.0
sec
In
65
–69
Px terminal
setting options
11 XCEL-L
0
–52
-
12 XCEL-M
49 XCEL-H
89
Multi-step
command delay
time
1
1
–5000
ms
Содержание G100
Страница 14: ......
Страница 16: ...5 5 7 5 kW 3 Phase ...
Страница 32: ...0 4 0 8 kW 1 5 2 2 kW 4 0 kW ...
Страница 48: ......
Страница 68: ......
Страница 81: ......
Страница 100: ......
Страница 116: ...trips automatic Reset Restart is not attempted and the Fire Mode Count is not increased ...
Страница 118: ......
Страница 130: ... Terminal connections for 3 wire operation 3 wire operation ...
Страница 140: ... PID control block diagram ...
Страница 165: ...Code and Features Description Code Description continuous rating ...
Страница 170: ......
Страница 186: ... Displayed as on the Keypad ...
Страница 200: ...provided signal output at 150 36 sec ...
Страница 216: ...Code and Features Description delay time delay time ...
Страница 219: ......
Страница 237: ......
Страница 253: ......
Страница 295: ......
Страница 314: ......
Страница 330: ...11 10 Remote Keypad Option It is comprised of a remote keypad and cables 1 m 2 m 3 m and 5 m Units mm ...
Страница 335: ...Manual Revision History Revision History No Date Edition Changes 1 2019 01 First Release ...