![LSIS G100 Скачать руководство пользователя страница 182](http://html.mh-extra.com/html/lsis/g100/g100_operation-manual_1944296182.webp)
Code and
Features
Description
6
Inverter
overload (IOL)
Outputs a signal when a fault is triggered from
a protective function operation by inverter
overload inverse proportion.
7
Under Load
(Underload)
Outputs a signal at load fault warning.
8
Fan Warning
(Fan Warning)
Outputs a signal at fan fault warning.
9
Stall
(motor stall)
Outputs a signal when a motor is overloaded
and stalled.
10
Over Voltage
(Over Voltage)
Outputs a signal when the inverter DC link
voltage rises above the protective operation
voltage.
11
Low Voltage
(Low Voltage)
Outputs a signal when the inverter DC link
voltage drops below the low voltage protective
level.
12
Over Heat
(Over Heat)
Outputs signal when the inverter overheats.
13
Lost
Command
(Lost
Command)
Outputs a signal when there is a loss of analog
input terminal and RS-485 communication
command at the terminal block. Outputs a
signal when communication power and
expansion an I/O power card is installed, and
also outputs a signal when losing analog input
and communication power commands.
14
RUN
Outputs a signal when operation command is
entered and the inverter outputs voltage. No
signal output during DC braking.
15
Stop
Outputs a signal at operation command off,
and when there is no inverter output voltage.
16
Steady
(Steady)
Outputs a signal in steady operation.
17
Inverter Line
(Inverter Line)
Outputs a signal while the motor is driven by
the inverter line.
18
Comm Line
(Comm Line)
Outputs a signal if a multi-function input
terminal (exchange) is input. For details, refer
to
on page
Содержание G100
Страница 14: ......
Страница 16: ...5 5 7 5 kW 3 Phase ...
Страница 32: ...0 4 0 8 kW 1 5 2 2 kW 4 0 kW ...
Страница 48: ......
Страница 68: ......
Страница 81: ......
Страница 100: ......
Страница 116: ...trips automatic Reset Restart is not attempted and the Fire Mode Count is not increased ...
Страница 118: ......
Страница 130: ... Terminal connections for 3 wire operation 3 wire operation ...
Страница 140: ... PID control block diagram ...
Страница 165: ...Code and Features Description Code Description continuous rating ...
Страница 170: ......
Страница 186: ... Displayed as on the Keypad ...
Страница 200: ...provided signal output at 150 36 sec ...
Страница 216: ...Code and Features Description delay time delay time ...
Страница 219: ......
Страница 237: ......
Страница 253: ......
Страница 295: ......
Страница 314: ......
Страница 330: ...11 10 Remote Keypad Option It is comprised of a remote keypad and cables 1 m 2 m 3 m and 5 m Units mm ...
Страница 335: ...Manual Revision History Revision History No Date Edition Changes 1 2019 01 First Release ...