4.18 Multi-Function Input Terminal Control
Filter time constants and the type of multi-function input terminals can be configured
to improve the response of input terminals.
Group Code
Name
Setting
Setting Range
Unit
In
85
Multi-function input
terminal On filter
10
0
–10000
ms
86
Multi-function input
terminal Off filter
3
0
–10000
ms
87
Multi-function input
terminal selection
0 0000*
-
-
88
NO/NC selection of
operation command
0
0
–1
-
90
Multi-function input
terminal status
0 0000*
-
-
* Displayed as
on the keypad.
Multi-Function Input Terminal Control Setting Details
Code and
Features
Description
In.84 DI Delay
Sel
Select whether or not to activate the time values set at In.85 and In.86.
If deactivated, the time values are set to the default values at In.85 and
In.86. If activated, the set time values at In.85 and In.86 are set to the
corresponding terminals.
Items
Enable state of terminal
Disable state of terminal
Keypad
In.85 DI On
Delay, In.86 DI
Off Delay
If the input terminal’s state is not changed during the set time, when the
terminal receives an input, it is recognized as On or Off.
In.87 DI NC/NO
Sel
Select terminal contact types for each input terminal. The position of the
indicator light corresponds to the segment that is on as shown in the
table below. With the bottom segment on, it indicates that the terminal
is configured as an A terminal (Normally Open) contact. With the top
segment on, it indicates that the terminal is configured as a B terminal
(Normally Closed) contact. Terminals are numbered P1
–P5, from right
to left.
Items
B contact status
A contact status
Keypad
In.88 Fx/Rx
Select whether to use the terminal set to Fx/Rx as NO (Normal Open)
Содержание G100
Страница 14: ......
Страница 16: ...5 5 7 5 kW 3 Phase ...
Страница 32: ...0 4 0 8 kW 1 5 2 2 kW 4 0 kW ...
Страница 48: ......
Страница 68: ......
Страница 81: ......
Страница 100: ......
Страница 116: ...trips automatic Reset Restart is not attempted and the Fire Mode Count is not increased ...
Страница 118: ......
Страница 130: ... Terminal connections for 3 wire operation 3 wire operation ...
Страница 140: ... PID control block diagram ...
Страница 165: ...Code and Features Description Code Description continuous rating ...
Страница 170: ......
Страница 186: ... Displayed as on the Keypad ...
Страница 200: ...provided signal output at 150 36 sec ...
Страница 216: ...Code and Features Description delay time delay time ...
Страница 219: ......
Страница 237: ......
Страница 253: ......
Страница 295: ......
Страница 314: ......
Страница 330: ...11 10 Remote Keypad Option It is comprised of a remote keypad and cables 1 m 2 m 3 m and 5 m Units mm ...
Страница 335: ...Manual Revision History Revision History No Date Edition Changes 1 2019 01 First Release ...