Make sure to install ground connection between the equipment and the motor for safe
use. Otherwise it may cause an electrical shock and result in personal injury or even
death.
•
Do not turn on the power if the product is damaged or faulty. If you find that the product
is faulty, disconnect the power supply and have the product professionally repaired.
•
The inverter becomes hot during operation. Avoid touching the inverter until it has
cooled to avoid burns. Avoid touching the inverter until it has cooled to avoid burns.
•
Do not allow foreign objects, such as screws, metal chips, debris, water, or oil to get
inside the inverter. Allowing foreign objects inside the inverter may cause the inverter
to malfunction or result in a fire.
•
Do not operate the switch with wet hands. Otherwise it may cause an electrical shock
and result in personal injury or even death.
•
Check the information about the protection level for the circuits and devices.
The connection terminals and parts below have electrical protection class 0. This
means that the protection class of the circuit depends on basic insulation and there is a
danger of electric shock if the basic insulation is not working properly. Therefore, take
the same protective measures as handling the power line when connecting wires to the
terminals or the device below, or when installing or using the devices.
- Multi-function Input: P1
–P5, CM
- Analog Input/Output: VR, V1, I2, AO
- Digital Output: 24, A1/B1/C1, A2/C2
- Communication: S+/ S-
- Fan
•
The protection level of this equipment is electrical protective class 1.
•
Do not change the inside of the product at your own discretion. This may result in injury
or damage to the product due to failure or malfunction. Also, products changed at your
own discretion will be excluded from the product warranty.
•
Do not use the inverter for single phase motor operation as it has been designed for
three phase motor operation. Using a single phase motor may damage the motor.
•
Do not place heavy objects on top of electric cables. Heavy objects may damage the
cable and result in electric shock.
Содержание G100
Страница 14: ......
Страница 16: ...5 5 7 5 kW 3 Phase ...
Страница 32: ...0 4 0 8 kW 1 5 2 2 kW 4 0 kW ...
Страница 48: ......
Страница 68: ......
Страница 81: ......
Страница 100: ......
Страница 116: ...trips automatic Reset Restart is not attempted and the Fire Mode Count is not increased ...
Страница 118: ......
Страница 130: ... Terminal connections for 3 wire operation 3 wire operation ...
Страница 140: ... PID control block diagram ...
Страница 165: ...Code and Features Description Code Description continuous rating ...
Страница 170: ......
Страница 186: ... Displayed as on the Keypad ...
Страница 200: ...provided signal output at 150 36 sec ...
Страница 216: ...Code and Features Description delay time delay time ...
Страница 219: ......
Страница 237: ......
Страница 253: ......
Страница 295: ......
Страница 314: ......
Страница 330: ...11 10 Remote Keypad Option It is comprised of a remote keypad and cables 1 m 2 m 3 m and 5 m Units mm ...
Страница 335: ...Manual Revision History Revision History No Date Edition Changes 1 2019 01 First Release ...