![LSIS G100 Скачать руководство пользователя страница 144](http://html.mh-extra.com/html/lsis/g100/g100_operation-manual_1944296144.webp)
Auto-Tuning Default Settings
Motor
Capacity
(kW)
Rated
Current (A)
No-load
Current
(A)
Rated Slip
Frequency
(Rpm)
Stator
Resistance
(
)
Leakage
Inductance
(mH)
200 V
0.2
1.1
0.8
100
14.0
40.4
0.4
1.9
1.0
90
6.42
38.8
0.75
3.3
1.7
70
2.951
25.20
1.5
5.9
2.7
70
1.156
12.07
2.2
8.6
3.9
50
0.809
6.44
3.7
13.8
5.7
50
0.485
4.02
5.5
20.0
6.2
50
0.283
3.24
7.5
25.5
7.4
50
0.183
2.523
400 V
0.2
0.7
0.5
100
28.00
121.2
0.4
1.1
0.6
90
19.40
117.0
0.75
1.9
0.9
70
8.97
76.3
1.5
3.4
1.7
70
3.51
37.3
2.2
4.3
2.3
50
3.069
24.92
3.7
6.9
3.2
50
1.820
15.36
5.5
11.5
3.6
50
0.819
9.77
7.5
15.0
4.4
50
0.526
7.58
Auto Tuning Parameter Setting Details
Code and
Features
Description
bA.20 Auto
Tuning
Select an auto tuning type and run it. Select one of the options and
then press the [ENT] key to run the auto tuning.
Configuration
Function
0
None
Auto tuning function is not enabled. If the auto
tuning function is ran, this will indicate that the
auto tuning is complete.
1
All
(Rotation
type)
Measures all motor parameters, including stator
resistance (Rs), leakage inductance (Lsigma),
stator inductance (Ls), no-load current (Noload
Curr), and rotor time constant (Tr) while the
motor is rotating.
As the motor is rotating while the parameters are
being measured, if the load is connected to the
motor spindle, the parameters may not be
measured accurately. For accurate
measurements, remove the load attached to the
motor spindle. However, note that the rotor time
constant (Tr) must be measured in a stopped
position.
2
All (static
Measures all parameters while the motor is in the
Содержание G100
Страница 14: ......
Страница 16: ...5 5 7 5 kW 3 Phase ...
Страница 32: ...0 4 0 8 kW 1 5 2 2 kW 4 0 kW ...
Страница 48: ......
Страница 68: ......
Страница 81: ......
Страница 100: ......
Страница 116: ...trips automatic Reset Restart is not attempted and the Fire Mode Count is not increased ...
Страница 118: ......
Страница 130: ... Terminal connections for 3 wire operation 3 wire operation ...
Страница 140: ... PID control block diagram ...
Страница 165: ...Code and Features Description Code Description continuous rating ...
Страница 170: ......
Страница 186: ... Displayed as on the Keypad ...
Страница 200: ...provided signal output at 150 36 sec ...
Страница 216: ...Code and Features Description delay time delay time ...
Страница 219: ......
Страница 237: ......
Страница 253: ......
Страница 295: ......
Страница 314: ......
Страница 330: ...11 10 Remote Keypad Option It is comprised of a remote keypad and cables 1 m 2 m 3 m and 5 m Units mm ...
Страница 335: ...Manual Revision History Revision History No Date Edition Changes 1 2019 01 First Release ...