F-47
TROUBLESHOOTING & REPAIR
4.
Listen for control relays CR1, CR2,
CR3, and CR4 to operate (audible click
of contacts closing) after a 5-second
delay.
a. If audible click of control relay con-
tacts closing is heard, Power Board
is probably OK.
NOTE: If there is still a possibility
that the Power Board is faulty, go to
Test B.
b. If audible click of control relay con-
tacts closing is not heard, Power
Board could be faulty. Go to Test B.
NOTE: Use Test A before disassembling
the unit.
TEST PROCEDURE
Test A
1.
Turn main power OFF.
2.
Position yourself at Switch Board area
of the machine (near Case Back) to lis-
ten to control relays CR1, CR2, CR3,
and CR4 operate (audible click of con-
tacts closing).
3.
Turn main power ON.
ELECTRIC SHOCK can kill.
Observe all safety precautions detailed
throughout this manual.
WARNING
POWER BOARD TEST