F-9
TROUBLESHOOTING & REPAIR
7. Test for 24 VAC between leads 223A
and 210.
a. If 24 VAC is measured, test is OK for
Fan Thermostat, Choke Thermostat,
Transformer T1, and Output Terminal
Switch S4. Go to step 8.
b. If 0 VAC is measured, test is not OK.
Test each of the following compo-
nents: Fan Thermostat, Choke
Thermostat, Transformer T1, and
Output Terminal Switch S4.
4. Position the Control Panel so you have
access to the Control Board by pulling
the Control Panel away from the
machine and moving it to the left.
Carefully let the Control Panel hang from
the machine.
5. Move Terminal Output Switch S4 to the
ON position.
6. Turn the main power ON.
OUTPUT PILOT CIRCUIT TEST
(continued)
G2527
CONTROL
210
223A
J5
J1
J2
J4
J3
FIGURE F.2 — CONTROL BOARD TEST POINTS.