F-10
TROUBLESHOOTING & REPAIR
8. Test for 15 VDC between leads 302 (+)
and 275D (–).
a. If 15 VDC is measured, test is OK for
15 VDC Power Supply and Trans-
former T1. Go to Protection Board
Output Test.
b. If 0 VDC is measured, test is not OK.
Test Power Board and Transformer
T1.
OUTPUT PILOT CIRCUIT TEST
(continued)
FIGURE F.3 — CONTROL BOARD TEST POINTS.
G2527
CONTROL
302
275D
J5
J1
J2
J4
J3