F-41
TROUBLESHOOTING & REPAIR
MATERIALS NEEDED
•
Analog voltmeter/ohmmeter (multimeter)
•
V300-I wiring diagrams
NOTE: Figure F.30 shows the Thermal
Protection AC Trigger Circuit.
CIRCUIT DESCRIPTION
The choke thermostat will open the normally
closed output trigger circuit if overheating
occurs due to excessive output loading
and/or excessive duty cycle.
The fan thermostat will open the normally
closed output trigger circuit if air flow is
blocked, the fan motor fails, or if the fan
blade breaks. This protection is necessary
to avoid overheating of machine compo-
nents during idle conditions.
ELECTRIC SHOCK can kill.
Observe all safety precautions detailed
throughout this manual.
– Perform input filter capacitor discharge
procedure.
WARNING
THERMAL PROTECTION AC TRIGGER CIRCUIT TEST