F-37
TROUBLESHOOTING & REPAIR
7. Test for 0 VDC between leads 311 and
313 on Protection Board.
a. If 0-1 VDC is present, the Protection
Board is OK. Go to step 8.
b. If 15 VDC is present, go to step 11.
OVERVOLTAGE PROTECTION DC TRIGGER CIRCUIT TEST
(continued)
FIGURE F.24 — PROTECTION BOARD TEST POINT.
PROTECTION
L7915
313
311
J8
J15