F-3
TROUBLESHOOTING & REPAIR
Troubleshooting Guide
— See Wiring Diagrams for location of specified
components. See Schematic Diagram for troubleshooting of specific circuits.
Observe Safety Guidelines
detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
Major physical or electrical damage
is observed when cover wrap-
around is removed.
Machine is dead — no output —
no fan — no display.
No output but fan operates and the
meter display is on.
POSSIBLE AREAS OF
MISADJUSTMENT(S)
Contact Lincoln Electric Service
Department (216-383-2531) or
1-800-833-9353 (WELD)
Power Switch must in ON position.
Check input voltage.
If machine is set for single-phase
operation, inspect to assure that
WHITE and BLACK leads are
connected properly and RED lead
is not connected and is insulated.
Check that input voltage set-up
switch and jumper A (the recon-
nect, auxiliary jumper) are in proper
position for input voltage being
used.
Check continuity of 3-amp slow
blow fuse located on reconnect
panel.
Output Terminal Switch or Remote
Trigger MUST be in ON position.
Local/Remote Switch must be in
LOCAL position unless remote
control device is attached to remote
receptacle.
If machine has not been used for a
long time and is connected for
380 VAC or higher, Capacitors may
need “conditioning.” See Input Filter
Capacitor Conditioning section.
POSSIBLE AREAS OF
MALFUNCTION(S)
1.
Power Switch (S1).
2.
Loose or broken wires between
Power Switch and Input
Rectifier (component D13).
3.
Broken leads to primary of
Auxiliary Transformer T1.
4.
Open primary coil of Auxiliary
Transformer T1.
1.
See Output Pilot Circuit test.
2.
See Thermal Protection AC
Trigger Circuit test.
3.
See Overvoltage Protection DC
Trigger Circuit test.
4.
See Static Capacitor Balance/
Dynamic Capacitor Balance
tests.
5.
See Switch PC Board test.
6.
Broken or loose connections on
high current-carrying parts of
machine (i.e., choke, output
bridges, output studes, main
transformer.
OUTPUT PROBLEMS
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln
Electric Service Department for technical troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353.
CAUTION