![Lincoln Electric INVERTEC V300-I Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/lincoln-electric/invertec-v300-i/invertec-v300-i_service-manual_1919081087.webp)
INVERTEC V300-I
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
F-44
TROUBLESHOOTING & REPAIR
7. Check that Output Terminal Switch S4 is
in the ON position (closed).
6. Test Auxiliary Transformer voltage for 24
VAC between leads 503 and 212D. See
Figure F.31.
a. If 24 VAC is present, transformer is
OK. Go to step 7.
b. If 0 VAC is present, test input voltage
to Auxiliary Transformer.
c. If input voltage to Auxiliary Transfor-
mer is correct, replace Auxiliary
Transformer.
d. If input voltage to Auxiliary Transfor-
mer is not correct, check Line Switch
S12 and connecting leads.
THERMAL PROTECTION AC TRIGGER CIRCUIT TEST
(continued)
FIGURE F.31 — THERMAL PROTECTION AC TRIGGER CIRCUIT.
CONTROL
BOARD
POWER
BOARD
T1
11J4
EXTERNAL
TRIGGER
S4 OUTPUT
TERMINAL
SWITCH
FAN
THERMOSTAT
CHOKE
THERMOSTAT
PART OF 14 PIN
AMPHENOL
NORMALLY CLOSED
NOTE:
WHEN THERMOSTATS
TRIP, THE CIRCUIT
WILL BE OPENED
9J6
10J6
#210
4J2
#223A
#224
#503A
#503
#212B
#212A
#212C
#223B
#212D
24
VOLTS
A.C.
4
D
C
2