![Lincoln Electric INVERTEC V300-I Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/lincoln-electric/invertec-v300-i/invertec-v300-i_service-manual_1919081057.webp)
INVERTEC V300-I
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
F-14
TROUBLESHOOTING & REPAIR
11. Repeat steps 1 thru 8, but measure
voltage between leads 306 (+) and 275
(-). If voltage is less than 1 VDC,
Protection Board is OK. If voltage is
greater than 14 VDC, Protection Board
is faulty. See Figure F.28.
10. Test for less than 1 VDC between leads
313 (-) and 311 (+).
a. If less than 1 VDC is measured, test
is OK and Protection Board is func-
tioning properly.
b. If more than 5 VDC is measured, go
to Static Capacitor Balance Test.
NOTE:. During voltage test, be cautious
to avoid positioning loose components
to avoid shorts and damage to equip-
ment.
PROTECTION BOARD OUTPUT TEST
(continued)
FIGURE F.7 — INSERTING PROBES.
PROTECTION
L7915
313
311
J8
J15