TROUBLESHOOTING & REPAIR
12. Remove the 5-amp fuse from the input
supply fuse holders.
13. Install 20-amp fuses and test under
load.
NOTE: A resistive-type grid load bank
is recommended.
14. Perform Retest After Repair.
8.
Turn on the machine.
9.
With the output free of a load, check the
open circuit voltages of the output.
10. Connect the machine for 440- or 575-
volt operation.
11. With the output free of a load, check
open circuit voltages of the output.
Voltage should be 70 VDC.
TEST AFTER REPAIR OF SWITCH BOARDS AND/OR CAPACITORS
(continued)