![Lincoln Electric INVERTEC V300-I Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/lincoln-electric/invertec-v300-i/invertec-v300-i_service-manual_1919081022.webp)
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
C-4
ACCESSORIES
INVERTEC V300-I
Invertec. (K864 remote control adapter and
K857 remote control are required for remote
output control.) See connection diagram
S19901.
6. Set meter polarity switch on rear of the
Invertec to coincide with wire feeder
polarity used. The wire feeder will not
display welding voltage.
NOTE: If K480 is not available, see con-
nection diagram S19404 for modification of
K291 or K404 LN-7 input cable with K867
universal adapter plug.
CONNECTING A LN-7 WIRE
FEEDER
1. Turn Invertec power switch OFF.
2. Connect K480 control cable from LN-7 to
Invertec control cable connector. The
control cable connector is located at the
rear of the Invertec.
3. Connect electrode cable to output termi-
nal of polarity required by electrode.
4. Connect work lead to other terminal.
5. Place local/remote switch in “Local” posi-
tion to allow output control at the
Only qualified persons should install, use or
service this machine.
using the disconnect switch at the fuse box
WARNING
Turn off input power to the Welding Power Source
Before connecting the wire feeder.
ELECTRIC
SHOCK
CAN KILL
N . A . W E L D I N G C A B L E M U S T B E S I Z E D F O R C U R R E N T A N D D U T Y C Y C L E O F A P P L I C A T I O N .
N . B . D I A G R A M S H O W S E L E C T R O D E P O S I T I V E . T O C H A N G E P O L A R I T Y , T U R N P O W E R " O F F " ,
R E V E R S E E L E C T R O D E A N D W O R K C A B L E A T P O W E R S O U R C E .
E L E C T R O D E C A B L E
T O L N - 7
T O
W O R K
-
+
1 4 P I N
A M P H E N O L
L N - 7
C O N T R O L
B O X
P O W E R S O U R C E
I N V E R T E C
K 8 6 4
K 4 8 0 - 7 I N P U T C A B L E
1 4 P I N
A M P H E N O L
K 8 5 7
R E M O T E C O N T R O L
K 8 1 2
H A N D A M P T R O L
K 8 7 0
F O O T A M P T R O L
N . C . K 4 8 0 - 7 I N P U T C A B L E C A N B E C O N N E C T E D D I R E C T L Y I F R E M O T E C O N T R O L I S N O T R E Q U I R E D .
6 P I N
A M P H E N O L
A D A P T E R
O R
O R
N . D . K 8 6 4 A D A P T E R C A N N O T B E U S E D W I T H A N L N - 2 5 .
W I T H 1 1 5 V A C
A U X I L I A R Y P O W E R
CLEVELAND, OHIO U.S.A.
S19901
R
1-25-91
K864 ADAPTER TO LN-7 & REMOTE CONTROL - CONNECTION DIAGRAM