![Lincoln Electric INVERTEC V300-I Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/lincoln-electric/invertec-v300-i/invertec-v300-i_service-manual_1919081024.webp)
C-6
ACCESSORIES
INVERTEC V300-I
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
polarity used. The wire feeder will now
display the welding voltage.
NOTE: K608-1 adapter is required in LN-9
GMA for LN-9 type control. K608-1 is
installed in line with P10 connection at the
LN-9 GMA voltage board. See connection
diagram S20607.
K442-1 pulse power filter board is also
required for GMAW but should be discon-
nected for FCAW.
If K596 is not available, see connection dia-
gram S20608 for modification of K196 LN-9
GMA input cable with K867 universal
adapter plug.
CONNECTING A LN-9 GMA
(Applies only to machines with 115V auxil-
iary)
1. Turn Invertec power switch OFF.
2. Connect K596 control cable assembly
from LN-9 GMA to Invertec control cable
connector. The control cable connector
is located at rear of the Invertec.
3. Connect electrode cable to output termi-
nal of polarity required by electrode.
Connect work lead to other terminal.
4. Place local/remote switch in “Remote”
position to allow output control at the
LN-9 GMA.
5. Set meter polarity switch on rear of the
Invertec to coincide with wire feeder
Only qualified persons should install, use or
service this machine.
using the disconnect switch at the fuse box
WARNING
Turn off input power to the Welding Power Source
Before connecting the wire feeder.
ELECTRIC
SHOCK
CAN KILL
N . A . W E L D I N G C A B L E M U S T B E S I Z E D F O R C U R R E N T A N D D U T Y C Y C L E O F A P P L I C A T I O N .
T O
W O R K
-
+
1 4 P I N
A M P H E N O L
E L E C T R O D E C A B L E
T O L N - 9 G M A
K 5 9 6 R E M O T E
C O N T R O L C A B L E
A S S E M B L Y
I N V E R T E C
P O W E R S O U R C E
W I T H 1 1 0 / 1 1 5 V A U X .
N . B . D I A G R A M S H O W S E L E C T R O D E P O S I T I V E . T O C H A N G E P O L A R I T Y , T U R N P O W E R " O F F " , R E V E R S E
E L E C T R O D E A N D W O R K C A B L E A T P O W E R S O U R C E . S E T M E T E R P O L A R I T Y S W I T C H O N R E A R
O F I N V E R T E C T O C O I N C I D E W I T H P O L A R I T Y U S E D . S E T L N - 9 G M A P O L A R I T Y S W I T C H A L S O .
N . D . F O R G M A W W E L D I N G , I N S T A L L P U L S E P O W E R F I L T E R K I T K 4 4 2 - 1 I N L N - 9 G M A .
N . C . I N S T A L L K 6 0 8 - 1 A D A P T E R I N L I N E W I T H P 1 0 T O L N - 9 G M A V O L T A G E B O A R D A N D S E C U R E T O
A D J A C E N T H A R N E S S W I T H W I R E T I E P R O V I D E D . T U R N " S T A R T " T R I M M E R O N V O L T A G E B O A R D F U L L Y ' C C W ' .
L N - 9 G M A W I T H
K 6 0 8 - 1 A N D
K 4 4 2 - 1 K I T S .
CLEVELAND, OHIO U.S.A.
R
S 2 0 6 0 7
P 1 0 ' , J 1 0
2
3
4
5
6
7
1 0
1 1
1 2
P 1 0 , J 1 0 '
2
3
4
5
6
1 1
1 2
7
3 . 9 K
K 6 0 8 - 1
C O N N E C T I O N
D E T A I L
5 3 0 A
5 2 1
5 0 0
5 0 0
5 2 4
C
B
5 3 3
9 - 1 1 - 9 2
LN-9 GMA WITH K596 CABLE TO INVERTEC - CONNECTION DIAGRAM
S20607