C-10
INVERTEC V300-I
NOTES
CONNECTING K799 HI-FREQ
KIT
1. Turn Invertec power switch OFF.
2. Use a K867 universal adapter to wire in
a 115V receptacle for the K799 plug on
leads 31, 32, and GND. Connect lead 21
to 225 from the K799.
NOTE: For remote control, accessories
K867, K775, K843, and K812 or K870 are
required. In this configuration, K775 remote
control sets the upper current limit of K812
hand Amptrol or K870 foot Amptrol. See
connection diagram S19432.
3. Connect an electrode cable from the
K799 to Invertec output terminal for
polarity preferred.
4. Connect work lead to other Invertec out-
put terminal.
5. Set polarity switch on rear of Invertec to
coincide with TIG polarity used.
6. Set local/remote switch appropriately for
control at the machine or using the
remote Amptrol.
7. Set mode switch to GTAW.
8. Energize output terminals utilizing output
terminals switch on front panel.
12/95