F-25
TROUBLESHOOTING & REPAIR
c. If 20 ohms or less is measured,
Resistor R4 is faulty and must be
replaced.
6. Repeat same procedures to test R5, R6,
and R7 per Table F.4.
5. Test for 25 ohms resistance from lead
401 to terminal 12 on Switch Board.
a. If 25 ohms is measured, Resistor R4
is OK.
b. If 30 ohms or more is measured,
Resistor R4 is faulty and must be
replaced.
SNUBBER RESISTORS TEST
(continued)
FIGURE F.14 — SWITCH BOARD TEST POINTS.
L8604-1
SWITCH
401
12
Check
Test Result
Conclusion
Next Test Step
Repair Action
Lead 401 to
25 ohms
OK
Continue
Terminal 12
>30 ohms
R4 open
Replace R4
<20 ohms
R4 faulty
Lead 402 to
25 ohms
OK
Continue
Terminal 9
>30 ohms
R5 open
Replace R5
<20 ohms
R5 faulty
Lead 403 to
25 ohms
OK
Continue
Terminal 12
>30 ohms
R6 open
Replace R6
<20 ohms
R6 faulty
Lead 404 to
25 ohms
OK
Continue
Terminal 9
>30 ohms
R7 open
Replace R7
<20 ohms
R7 faulty
> = GREATER THAN
< = LESS THAN
TABLE F.4 — SNUBBER RESISTORS TEST.