F-17
TROUBLESHOOTING & REPAIR
Replace Protection Board and go to
Dynamic Capacitor Balance Test.
b. If more than 25 VDC difference is
measured between each Switch
Board, test each of the following
components:
•
Capacitors C1 and C2 and
Resistors R1 and R9.
•
(575 VAC only machines —
Capacitors C1, C2, C14, and
C15; and Resistors R1 and R9.)
3. Record VDC measured for each Switch
Board and determine the difference in
VDC.
NOTE: The following measurements
should result based on VAC input.
TABLE F.1 — EXPECTED VOLTAGE
READINGS.
a. If less than 25 VDC difference is
measured between each Switch
Board, then capacitive balance is OK.
•
This indicates that Capacitors C1
and C2, Resistors R1 and R9 are
functioning properly.
•
(575 VAC only machines —
Capacitors C1, C2, C14, and
C15; Resistors R1 and R9.)
STATIC CAPACITOR BALANCE TEST
(continued)
VDC at terminals 9
and 12 should be
If VAC Input is:
approximately:
575VAC
407 VDC
460 VAC
325 VDC
440 VAC
311 VDC
415 VAC
293 VDC
380 VAC
269 VDC